The AGROS rotary tillers boast high durability thanks to their sturdy design,
and help with efficient soil cultivation through a variety of models.
A single-stage type that can be mounted on 35~45 HP tractors.
This compact model is suitable for both paddy and field work.
It boasts excellent strength and durability by applying
a frame-type main deck,
high-strength pipe, and special material blade flange.
Model |
![]() (mm) |
![]() (mm) |
![]() (mm) |
![]() (mm) |
![]() (mm) |
![]() Flanges (EA) |
![]() Blades (EA) |
![]() Speed (rpm) |
![]() (hp) |
![]() |
![]() (kg) |
---|---|---|---|---|---|---|---|---|---|---|---|
AR2165NC | 1,875 | 1,030 | 840 | 1,615 | 120~150 | 6 | 36 | 165.8 / 540rpm |
35~40 | 615 | 390 |
AR2175NC | 1,980 | 1,730 | 7 | 42 | 40~45 | 410 |
* These specifications may be changed without prior notice to improve performance and quality.
Feature 01
Up to 70 HP single-speed gearbox
(Oil gauge installed as standard)
Feature 02
Spring tension and rolling type back cover
(Using high tensile steel plate)
Feature 03
Main deck with high-strength double frame
structure
Feature 04
Feature 05
Feature 06
Feature 07
Feature 08
Versatile with sturdy structure and various
mounting holes top master
▲ : Check
● : Replace
Inspection Point | Oil Type | Oil Inspection Time | Volume | Instructions | |||
---|---|---|---|---|---|---|---|
Everyday | 50 Hours Everyday |
100 Hours Everyday |
200 Hours Everyday |
||||
Gearbox | Gear Oil | ▲ | ▲ | ● | 3.0 | Check the oil level using the oil gauge, and replace or add oil as needed. | |
Side Cover | Gear Oil | ▲ | ▲ | ● | 2.5 | If oil does not flow out when you open the inspection plug, add oil. If oil flows out, check the oil's color and foreign matter condition, and replace the oil if necessary. |
|
Bearing Cover | Gear Oil | ▲ | ▲ | 0.2 | The oil level is adequate when it reaches the inspection plug. | ||
Universal Joint | Grease | ▲ | ▲ | Grease Nipple Injection | |||
Conclusion of Each Part |
▲ | ▲ | Check the attachment status of the top master’s plow blade and the plow shaft. |
||||
Blade | ▲ | ▲ | Inspect bolts and nuts for any damage or deformation. |
※ After the initial 50 hours of use, replace all areas where gear oil is injected.
※ When replacing oil, dispose of waste at a designated, authorized waste disposal facility.
Contact Us